Avoid Sample Contamination
When sampling with a vacuum pump, follow these simple tips to avoid sample contamination:
- After measuring the length or depth of the fill port tube, reservoir or dipstick retaining tube, add six inches and mark the measurement on the tubing. Cut the tubing 12 inches beyond this mark, insert it into the pump and tighten the lock ring.
- To avoid drawing settled debris into the sample, insert the tubing into the fill port, reservoir or dipstick retaining tube only to the mark on the tubing. Do not allow contact between the tubing and the bottom of the sump.
- Activate plunger until sample jar is only ¾ full. Avoid filling sample jar completely. Fluid can back up into pump and contaminate future samples.
- Remove filled jar from pump and replace the jar lid before wiping sample jar clean.
- Discard tubing after taking each sample to avoid contaminating next sample.
Print this Technical Bulletin (PDF - 94K)
Quick Links
News
POLARIS Laboratories® Expands into Central America
POLARIS Laboratories® is again extending its global reach with a new laboratory in Guatemala City. The expansion supports the company's global strategy for continued growth and is indicative of the strength and potential of the Central American market.
POLARIS Laboratories® Makes Inc. 5000 List Third Year in a Row
For the third year in a row, POLARIS Laboratories® has been named to Inc. Magazine's List of 5000 Fastest Growing Privately-Held Companies in America.
Training
Nashville
Cooling Systems Maintenance
March 6, 2012Nashville
Oil Analysis
March 7-8, 2012Houston
Cooling Systems Maintenance
April 17, 2012
Tradeshows & Conferences
UMA Motorcoach Expo
Long Beach, CA
February 8-12, 2012PepsiCo Summit & Tradeshow
San Antonio, TX
February 13-16, 2012