RPVOT

Definition:

RPVOT (Rotary Pressure Vessel Oxidation Test) measures the oxidation stability of a turbine oil. The sample is placed in a vessel that contains a polished copper coil. The vessel is then charged with oxygen then placed in a bath at a constant temperature of 150°C. Oxidation stability is expressed in terms of the time required to achieve a 25.4 psig pressure drop from maximum pressure.

Standard Test Method Used:

ASTM D2272

Reporting Measurement:

Minutes

Amount of Sample Needed:

200 mL

Test Limitation:

Test is primarily used for turbine and compressor oils.

RPVOT illustration

(click on image for larger version)


Top

News

POLARIS Laboratories® Announces 2013 Public Training Classes

POLARIS Laboratories®, an innovative leader in the fluid analysis industry, has announced its public training class schedule for 2013. Whether attendees are just beginning to establish fluid analysis best practices or they've been in the industry for years, these classes will expand their knowledge of oils and coolants and help them understand the importance of doing fluid analysis and doing it well.

Read More


POLARIS Laboratories® Opens New Fluid Testing Lab in Moscow, Russia

The company has now expanded into Russia with the opening of POLARIS Laboratories® Russia, the official representative of POLARIS Laboratories®, located in Moscow.

Read More


Training

  • Orlando
    Oil Analysis
    July 24-25, 2013

  • Oklahoma City
    Oil Analysis
    August 28-29, 2013

  • Philadelphia
    Cooling Systems Maintenance
    September 24, 2013

View complete schedule and registration information


Tradeshows & Conferences

  • Oil Sands Trade Show
    Fort McMurray, AB
    September 10-11, 2013



View all tradeshows