RPVOT
Definition:
RPVOT (Rotary Pressure Vessel Oxidation Test) measures the oxidation stability of a turbine oil. The sample is placed in a vessel that contains a polished copper coil. The vessel is then charged with oxygen then placed in a bath at a constant temperature of 150°C. Oxidation stability is expressed in terms of the time required to achieve a 25.4 psig pressure drop from maximum pressure.
Standard Test Method Used:
Reporting Measurement:
Minutes
Amount of Sample Needed:
200 mL
Test Limitation:
Test is primarily used for turbine and compressor oils.
Quick Links
News
POLARIS Laboratories® Announces 2013 Public Training Classes
POLARIS Laboratories®, an innovative leader in the fluid analysis industry, has announced its public training class schedule for 2013. Whether attendees are just beginning to establish fluid analysis best practices or they've been in the industry for years, these classes will expand their knowledge of oils and coolants and help them understand the importance of doing fluid analysis and doing it well.